Robin C01061 Manual Pagina 14

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 56
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 13
gf13
13
Manual Robin Compact SIP ENG - v. 3.0.1
4 System installation
4.1 Requirements prior to installation

Network connection with PoE (Power over Ethernet is used to power the door intercom; the
power supply must be 802.3af compatible).

PC with web browser.

The following web browsers are supported:
- FireFox
- Safari
- Google Chrome

USB stick with the ‘Robin Discovery Utility’ software (supplied)

Network with or without DHCP support
(DHCP support is recommended)
Network cable, the cable may not be longer than 100 metres
Optional - Two-core cable for door switch operation
4.2 Connecting the Robin SIP to a network

Connect the Robin SIP to the network via the network connection socket on the rear.

The Robin SIP will now boot. This can take up to 60 seconds.
! Note: The length of the Ethernet cable may not exceed 100 metres. This is a limit of the Ethernet
standard. !
Vista de pagina 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 55 56

Comentarios a estos manuales

Sin comentarios